The Pneumatix compressor range covers three output levels and five configurations. PM10 and PM20 are available as integrated Total Air Stations or compressor-only Base Mounts. PM30 is available as a Base Mount.
Every Pneumatix compressor is rated to a maximum working pressure of 10 bar (145 PSI). Airflow is published at 8 bar, which is the standard comparison point, so our figures can be compared fairly against machines that never reach 10 bar.
Total Air Station or Base Mount?
Choose a Total Air Station when you want the compressor, receiver and main air-treatment components supplied as one receiver-mounted package. Choose a Base Mount when the receiver, dryer and filtration need to be selected separately, already exist or need to be positioned elsewhere.
Total Air Stations
PM10 and PM20 receiver-mounted packages with the receiver, refrigerated dryer and inline filtration included.
Base Mounts
PM10, PM20 and PM30 compressor-only configurations for separately selected storage and air treatment.
The Pneumatix compressor range

Base Mount
PM10 Base Mount
PM10VSD
- 1,000 L/min at 8 bar
- 10 bar max pressure
- 7.5 kW / 10 HP
- Compressor only
Recommended Retail Price $4,799 inc GST, excludes delivery

Total Air Station
PM10 Total Air Station
PM10300VSD
- 1,000 L/min at 8 bar
- 10 bar max pressure
- 7.5 kW / 10 HP
- 300 L receiver
- 1.0 micron pre-filter
- 0.01 micron post-filter
Recommended Retail Price $7,699 inc GST, excludes delivery

Base Mount
PM20 Base Mount
PM20VSD
- 2,100 L/min at 8 bar
- 10 bar max pressure
- 15 kW / 20 HP
- Compressor only
Recommended Retail Price $7,799 inc GST, excludes delivery

Total Air Station
PM20 Total Air Station
PM20500VSD
- 2,100 L/min at 8 bar
- 10 bar max pressure
- 15 kW / 20 HP
- 500 L receiver
- 1.0 micron pre-filter
- 0.01 micron post-filter
Recommended Retail Price $11,199 inc GST, excludes delivery

Base Mount
PM30 Base Mount
PM30VSD
- 3,200 L/min at 8 bar
- 10 bar max pressure
- 22 kW / 30 HP
- Compressor only
Recommended Retail Price $10,199 inc GST, excludes delivery
Compare PM10, PM20 and PM30
| Product | Model | Configuration | Motor power | FAD at 8 bar | Max pressure | Receiver | Dryer | Pre-filter | Post-filter | 3Ø Circuit Breaker |
|---|---|---|---|---|---|---|---|---|---|---|
| PM10 Base Mount | PM10VSD | Base Mount | 7.5 kW / 10 HP | 1,000 L/min (35 CFM) at 8 bar | 10 bar / 145 PSI | – | – | – | – | D20 |
| PM10 Total Air Station | PM10300VSD | Total Air Station | 7.5 kW / 10 HP | 1,000 L/min (35 CFM) at 8 bar | 10 bar / 145 PSI | 300 litres | 1,200 L/min | 1.0 micron | 0.01 micron | D20 |
| PM20 Base Mount | PM20VSD | Base Mount | 15 kW / 20 HP | 2,100 L/min (74 CFM) at 8 bar | 10 bar / 145 PSI | – | – | – | – | D32 |
| PM20 Total Air Station | PM20500VSD | Total Air Station | 15 kW / 20 HP | 2,100 L/min (74 CFM) at 8 bar | 10 bar / 145 PSI | 500 litres | 2,400 L/min | 1.0 micron | 0.01 micron | D32 |
| PM30 Base Mount | PM30VSD | Base Mount | 22 kW / 30 HP | 3,200 L/min (113 CFM) at 8 bar | 10 bar / 145 PSI | – | – | – | – | D50 |
PM10 Base Mount
- Model
- PM10VSD
- Configuration
- Base Mount
- Motor power
- 7.5 kW / 10 HP
- FAD at 8 bar
- 1,000 L/min (35 CFM) at 8 bar
- Max pressure
- 10 bar / 145 PSI
- Receiver
- –
- Dryer
- –
- Pre-filter
- –
- Post-filter
- –
- 3Ø Circuit Breaker
- D20
- Best suited to
- The site already has a suitable receiver, A larger or separately positioned receiver is preferred, Dryer and filtration requirements need to be selected independently, The compressor is being installed as part of a planned plant-room system, The site may expand its storage or air-treatment system later
PM10 Total Air Station
- Model
- PM10300VSD
- Configuration
- Total Air Station
- Motor power
- 7.5 kW / 10 HP
- FAD at 8 bar
- 1,000 L/min (35 CFM) at 8 bar
- Max pressure
- 10 bar / 145 PSI
- Receiver
- 300 litres
- Dryer
- 1,200 L/min
- Pre-filter
- 1.0 micron
- Post-filter
- 0.01 micron
- 3Ø Circuit Breaker
- D20
- Best suited to
- mechanical workshops with verified demand within the PM10 output level, tyre and service facilities, smaller fabrication applications, sites where an integrated package suits the available space
PM20 Base Mount
- Model
- PM20VSD
- Configuration
- Base Mount
- Motor power
- 15 kW / 20 HP
- FAD at 8 bar
- 2,100 L/min (74 CFM) at 8 bar
- Max pressure
- 10 bar / 145 PSI
- Receiver
- –
- Dryer
- –
- Pre-filter
- –
- Post-filter
- –
- 3Ø Circuit Breaker
- D32
- Best suited to
- A suitable receiver is already installed, A different receiver capacity is required, Air treatment must be independently specified, The compressor is part of a larger plant-room arrangement, The site needs flexibility for future system changes
PM20 Total Air Station
- Model
- PM20500VSD
- Configuration
- Total Air Station
- Motor power
- 15 kW / 20 HP
- FAD at 8 bar
- 2,100 L/min (74 CFM) at 8 bar
- Max pressure
- 10 bar / 145 PSI
- Receiver
- 500 litres
- Dryer
- 2,400 L/min
- Pre-filter
- 1.0 micron
- Post-filter
- 0.01 micron
- 3Ø Circuit Breaker
- D32
- Best suited to
- larger mechanical workshops, tyre and service facilities with multiple users, fabrication and engineering sites, CNC and manufacturing environments, other sites with greater simultaneous demand
PM30 Base Mount
- Model
- PM30VSD
- Configuration
- Base Mount
- Motor power
- 22 kW / 30 HP
- FAD at 8 bar
- 3,200 L/min (113 CFM) at 8 bar
- Max pressure
- 10 bar / 145 PSI
- Receiver
- –
- Dryer
- –
- Pre-filter
- –
- Post-filter
- –
- 3Ø Circuit Breaker
- D50
- Best suited to
- Larger automotive facilities, Fabrication and engineering sites, CNC and manufacturing environments, Other industrial processes with sustained or simultaneous air demand
A dash means that item is not supplied with that configuration. A Base Mount is the same compressor on rubber feet, supplied without receiver, dryer or filtration. Dryers hold a 2-10 °C pressure dew point on R134a refrigerant, and the air treatment is rated above the compressor it serves.
Why the 10 bar rating matters. Flow is quoted at 8 bar so it compares directly against machines that do not reach 10 bar. The extra pressure is not a number on a sheet: the variable-speed controller can be programmed to cut in and out at the pressure points you choose, so the system can be set to hold above 8 bar and still have headroom when demand peaks. A machine rated to 8 bar has nothing left above 8 bar to give.
Breaker sizes are our recommendation for the three-phase compressor supply. A Total Air Station also needs a 10 A general purpose outlet for its dryer. The final circuit design is the installing electrician’s under AS/NZS 3000.
Confirm more than horsepower
Final selection should account for real simultaneous air demand, operating pressure, duty cycle, receiver storage, air treatment, leaks, future growth, available electrical capacity and site conditions.
Complete the compressed-air system
Building a Base Mount system? Refrigerated air drying, filtration and receiver capacity can be selected separately to suit the installation.
Need help narrowing the range?
Work directly with your Pneumatix dealer, or ask Pneumatix to review the application and help identify the most appropriate starting point.